PRODUCTS >> DRILLING FLUIDS & OIL WELL >> Ultrasonic Cement Analyzer(UCA)

Low Temperature ULTRASONIC Static GEL Strength Analyzer

Date:2020-05-10 13:57:34 Clicks:463
Low Temperature ULTRASONIC Static GEL Strength Analyzer


Low Temperature ULTRASONIC Static GEL Strength Analyzer

Model LSX-5265

The SENXIN GROUP Low temperature Ultrasonic Static Gel Strength Analyzers (SGSA) is an instrument that measures the static gel strength of API cement under Deepsea Low temperature and high-pressure conditions. The instrument captures ultrasonic signals that are passed through the sample then performs post-processing of the data to determine the static gel strength (SGS) versus time plot.

 

Each LSX-5265 autoclave connected as part of the SGSA system is equipped with an internal processor board that sends and receives an ultrasonic pulse through the slurry, performs digital signal processing of captured data and, as an option, measures the transit time of the pulse through the slurry.

After the processor board computes the SGS data, it is sent to the I/O board located on the rear of the autoclave. The I/O board is connected to the RS-232 serial communication port located on the rear of the PC or to another autoclave I/O board by a four-wire RS-485 communication cable.

 

FEATURES:

1.   Non-Destructive Method

2.   High pressure sample vessel

3.   Real-time display of gel development graph, Gel strength development Graph, Compressive Strength Development Graph, Temperature and pressure Graphs, and Ultrasonic Signal transmit time.

4.   Automatic Data acquisition and saving against power failure

5.   System pressure control with a pressure gauge away from compressed air pressure

6.   The upper limit of pressure control with a high-pressure overflow valve

7.   External pressure source port

8.   Automatically temperature control

9.   Multiple temperature and pressure protection

10. Small, transportable size for field locations and mobile labs

11. External chiller for low temperature test

12. Timely after-sales service

 

SPECIFICATION:

Temperature range :0-50 (32 to 122)

Maximum pressure:138MPa /20,015PSI

Pressure medium: Water

Compressed air:0.3 to 0.7MPa (44 to 102 PSI)

Cooling Water:0.2 to 0.6MPa (29 to 87 PSI)

Ambient Temperature:10 to 50 (50 to 122)

Ambient Humidity:0 to 70%

Heater power: 2,000 watts

Power Supply: Chiller:110/220 VAC ,50/60HZ ,16A

             Instrument: 110/220 VAC ,50/60HZ ,5A

Dimensions:638*560*994 mm (25*22*39in)

Weight: 125kg / 276lb